دورية أكاديمية

Comparison of clinical outcomes of Eyecryl toric and Alcon toric intra-ocular lenses – A real world study

التفاصيل البيبلوغرافية
العنوان: Comparison of clinical outcomes of Eyecryl toric and Alcon toric intra-ocular lenses – A real world study
المؤلفون: Nilay Reddy Korpole, Padma Kurada, Neetha I R Kuzhuppilly, Madhukar Reddy Korpole
المصدر: Indian Journal of Ophthalmology, Vol 71, Iss 8, Pp 2972-2977 (2023)
بيانات النشر: Wolters Kluwer Medknow Publications, 2023.
سنة النشر: 2023
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: astigmatism, iol, phaco-emulsification, toric, visual acuity, Ophthalmology, RE1-994
الوصف: Purpose: To compare the visual outcomes and residual astigmatism following implantation of Eyecryl toric versus Alcon AcrySof IQ toric intra-ocular lenses (IOLs). Methods: This retrospective, observational study included 143 eyes of 141 patients who underwent phaco-emulsification, followed by implantation of Eyecryl toric IOL (n = 83 eyes) or Alcon toric IOL (n = 60 eyes) in an eye hospital in South India from 2018 to 2021. At 1 month post-op, the uncorrected distance visual acuity (UCVA), best corrected distance visual acuity (BCVA), and residual astigmatism of the toric IOL were compared and analyzed. Results: The mean pre-op corneal astigmatism was 2.02 ± 0.81 D and 1.70 ± 0.68 D in the Alcon and Eyecryl groups, respectively (P = 0.005). The mean post-op corneal astigmatism at 1 month was 0.50 ± 0.51 D and 0.36 ± 0.42 D in the Alcon and Eyecryl groups, respectively, with no statistically significant difference between them (P = 0.87). The mean post-op UCVA in logarithm of minimum angle of resolution (logMAR) at 1 month was similar between the groups at 0.17 ± 0.18 and 0.17 ± 0.16 in the Alcon and Eyecryl groups, respectively (P = 0.98). The mean post-op BCVA in logMAR at 1 month was 0.06 ± 0.09 and 0.03 ± 0.10 in the Alcon and Eyecryl groups, respectively (P = 0.02). Conclusion: Both Eyecryl toric and Alcon AcrySof IQ toric IOLs showed comparable post-operative outcomes in terms of UCVA and residual astigmatism. The post-op BCVA was clinically similar between groups but statistically better in the Eyecryl toric group.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0301-4738
1998-3689
Relation: http://www.ijo.in/article.asp?issn=0301-4738;year=2023;volume=71;issue=8;spage=2972;epage=2977;aulast=Korpole; https://doaj.org/toc/0301-4738; https://doaj.org/toc/1998-3689
DOI: 10.4103/IJO.IJO_3403_22
URL الوصول: https://doaj.org/article/894b8fd78a6c4121a3205034664fc991
رقم الأكسشن: edsdoj.894b8fd78a6c4121a3205034664fc991
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:03014738
19983689
DOI:10.4103/IJO.IJO_3403_22