A comprehensive and efficient quality assurance program for an image-guided small animal irradiation system

التفاصيل البيبلوغرافية
العنوان: A comprehensive and efficient quality assurance program for an image-guided small animal irradiation system
المؤلفون: Severin Kampfer, Manuela A. Duda, Sophie Dobiasch, Stephanie E. Combs, Jan J. Wilkens
المصدر: Zeitschrift für Medizinische Physik, Vol 32, Iss 3, Pp 261-272 (2022)
بيانات النشر: Elsevier, 2022.
سنة النشر: 2022
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
مصطلحات موضوعية: Small animal irradiator, Quality assurance, SARRP, Image-guided radiotherapy, Preclinical radiotherapy, Medical physics. Medical radiology. Nuclear medicine, R895-920
الوصف: In the field of preclinical radiotherapy, many new developments were driven by technical innovations. To make research of different groups comparable in that context and reliable, high quality has to be maintained. Therefore, standardized protocols and programs should be used. Here we present a guideline for a comprehensive and efficient quality assurance program for an image-guided small animal irradiation system, which is meant to test all the involved subsystems (imaging, treatment planning, and the irradiation system in terms of geometric accuracy and dosimetric aspects) as well as the complete procedure (end-to-end test) in a time efficient way. The suggestions are developed on a Small Animal Radiation Research Platform (SARRP) from Xstrahl (Xstrahl Ltd., Camberley, UK) and are presented together with proposed frequencies (from monthly to yearly) and experiences on the duration of each test. All output and energy related measurements showed stable results within small variation. Also, the motorized parts (couch, gantry) and other geometrical alignments were very stable. For the checks of the imaging system, the results are highly dependent on the chosen protocol and differ according to the settings. We received nevertheless stable and comparably good results for our mainly used protocol. All investigated aspects of treatment planning were exactly fulfilled and also the end-to-end test showed satisfying values. The mean overall time we needed for our checks to have a well monitored machine is less than two hours per month.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0939-3889
Relation: http://www.sciencedirect.com/science/article/pii/S0939388922000320; https://doaj.org/toc/0939-3889
DOI: 10.1016/j.zemedi.2022.02.004
URL الوصول: https://doaj.org/article/8ca4beca8a8f478c859aaaace0cb2afc
رقم الأكسشن: edsdoj.8ca4beca8a8f478c859aaaace0cb2afc
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09393889
DOI:10.1016/j.zemedi.2022.02.004