دورية أكاديمية

Development of a Rapid Gold Nanoparticle-Based Lateral Flow Immunoassay for the Detection of Dengue Virus

التفاصيل البيبلوغرافية
العنوان: Development of a Rapid Gold Nanoparticle-Based Lateral Flow Immunoassay for the Detection of Dengue Virus
المؤلفون: Cynthia Martinez-Liu, Carlos Machain-Williams, Natalia Martinez-Acuña, Sonia Lozano-Sepulveda, Kame Galan-Huerta, Daniel Arellanos-Soto, Mayra Meléndez-Villanueva, Diana Ávalos-Nolazco, Katya Pérez-Ibarra, Sergio Galindo-Rodríguez, Aurora de Jesús Garza-Juarez, Ana María Rivas-Estilla
المصدر: Biosensors, Vol 12, Iss 7, p 495 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Biotechnology
مصطلحات موضوعية: dengue virus, gold nanoparticle, lateral flow assay, biosensor, immunochromatographic strip, point-of-care test (POCT), Biotechnology, TP248.13-248.65
الوصف: Flavivirus detection in humans and mosquito reservoirs has been an important issue since it can cause a variety of illnesses and could represent a health problem in geographical zones where the vector is endemic. In this work, we designed and characterized a biosensor based on gold nanoparticles (AuNPs) and antibody 4G2 for the detection of dengue virus (DENV) in vitro, obtaining different conjugates (with different antibody concentrations). The AuNP–4G2 conjugates at concentrations of 1, 3, and 6 µg/mL presented an increase in the average hydrodynamic diameter compared to the naked AuNPs. Also, as part of the characterization, differences in the UV-Vis absorbance spectrum and electrophoretic migration were observed between the conjugated AuNPs (with BSA or antibody) and naked AuNPs. Additionally, we used this biosensor (AuNP–4G2 conjugate with 3 µg/mL antibody) in the assembly of a competitive lateral flow assay (LFA) for the development of an alternative test to detect the flavivirus envelope protein in isolated DENV samples as a future tool for dengue detection (and other flaviviruses) in the mosquito vector (Aedesaegypti) for the identification of epidemic risk regions. Functionality tests were performed using Dengue virus 2 isolated solution (TCID50/mL = 4.58 × 103) as a positive sample and PBS buffer as a negative control. The results showed that it is possible to detect Dengue virus in vitro with this gold nanoparticle-based lateral flow assay with an estimated detection limit of 5.12 × 102 PFU. We suggest that this biosensor could be used as an additional detection tool by coupling it to different point-of-care tests (POCT) for the easy detection of other flaviviruses.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2079-6374
Relation: https://www.mdpi.com/2079-6374/12/7/495; https://doaj.org/toc/2079-6374
DOI: 10.3390/bios12070495
URL الوصول: https://doaj.org/article/ea8cd54c6cfc496a9b6dd9974c21feba
رقم الأكسشن: edsdoj.8cd54c6cfc496a9b6dd9974c21feba
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20796374
DOI:10.3390/bios12070495