دورية أكاديمية

Comparative evaluation of a laboratory-developed real-time PCR assay and RealStar® Adenovirus PCR Kit for quantitative detection of human adenovirus

التفاصيل البيبلوغرافية
العنوان: Comparative evaluation of a laboratory-developed real-time PCR assay and RealStar® Adenovirus PCR Kit for quantitative detection of human adenovirus
المؤلفون: Samson S. Y. Wong, Cyril C. Y. Yip, Siddharth Sridhar, Kit-Hang Leung, Andrew K. W. Cheng, Ami M. Y. Fung, Ho-Yin Lam, Kwok-Hung Chan, Jasper F. W. Chan, Vincent C. C. Cheng, Bone S. F. Tang, Kwok-Yung Yuen
المصدر: Virology Journal, Vol 15, Iss 1, Pp 1-9 (2018)
بيانات النشر: BMC, 2018.
سنة النشر: 2018
المجموعة: LCC:Infectious and parasitic diseases
مصطلحات موضوعية: Human adenovirus, Real-time PCR, RealStar® Adenovirus PCR Kit, Infectious and parasitic diseases, RC109-216
الوصف: Abstract Background Human adenoviruses are common causes of community-acquired respiratory tract and enteric infections. Severe disseminated infections with high mortality rates may be seen in immunocompromised individuals. An accurate and cost-effective quantitative assay is essential not only for laboratory diagnosis of adenoviral infections, but also for monitoring of response to antiviral treatment. The diagnostic performance of an in-house quantitative polymerase chain reaction assay was compared to a commercial system. Methods The analytical sensitivity, specificity, linearity, precision and accuracy of an in-house adenovirus quantitative polymerase chain reaction assay were evaluated against the RealStar® Adenovirus PCR Kit (Altona Diagnostics GmbH, Hamburg, Germany), using 122 clinical specimens and 18 proficiency testing samples. Results Linear regression analysis of the quantitative results by the in-house assay showed the dynamic range from 2.60 to 9 log10 (plasma) and 2.94 to 9 log10 (viral transport medium) copies/mL, with the coefficient of determination (R2) of 0.996 and 0.998, respectively. A dilution series demonstrated the limits of detection and lower limits of quantification for plasma were 2.06 log10 and 2.60 log10 copies/mL and those for viral transport medium were 2.31 log10 and 2.94 log10 copies/mL respectively. The precision of the in-house assay was highly reproducible among runs with coefficients of variance ranging from 0.07 to 3.21% for plasma and 0.17% to 2.11% for viral transport medium. A comparison of 52 matched samples showed an excellent correlation between the quantitative viral loads measured by the in-house assay and the RealStar® Adenovirus PCR Kit (R2 = 0.984), with an average bias of − 0.16 log10 copies/mL. Conclusions The in-house adenovirus assay is a sensitive and reliable assay with lower cost for the detection and quantification of adenoviral DNA when compared to the RealStar® Adenovirus PCR Kit.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1743-422X
Relation: http://link.springer.com/article/10.1186/s12985-018-1059-7; https://doaj.org/toc/1743-422X
DOI: 10.1186/s12985-018-1059-7
URL الوصول: https://doaj.org/article/8e09c7e80a0b4b4cbcc2b5de51fb8617
رقم الأكسشن: edsdoj.8e09c7e80a0b4b4cbcc2b5de51fb8617
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1743422X
DOI:10.1186/s12985-018-1059-7