دورية أكاديمية

Ab Externo Imaging of Human Episcleral Vessels Using Fiberoptic Confocal Laser Endomicroscopy

التفاصيل البيبلوغرافية
العنوان: Ab Externo Imaging of Human Episcleral Vessels Using Fiberoptic Confocal Laser Endomicroscopy
المؤلفون: Ken Y. Lin, Sameh Mosaed
المصدر: Journal of Ophthalmic & Vision Research, Vol 14, Pp 1-10 (2019)
بيانات النشر: Knowledge E, 2019.
سنة النشر: 2019
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: Aqueous Outflow, Laser Imaging, Minimally Invasive Glaucoma Surgery, Ophthalmology, RE1-994
الوصف: Purpose: There is a growing interest in targeting minimally invasive surgery devices to the aqueous outflow system to optimize treatment outcomes. However, methods to visualize functioning, large-caliber aqueous and episcleral veins in-vivo are lacking. This pilot study establishes an ex-vivo system to evaluate the use of a confocal laser microendoscope to noninvasively image episcleral vessels and quantify regional flow variation along the limbal circumference. Methods: A fiber-optic confocal laser endomicroscopy (CLE) system with lateral and axial resolution of 3.5 μ m and 15 μ m, respectively, was used on three porcine and four human eyes. Diluted fluorescein (0.04%) was injected into eyes kept under constant infusion. The microprobe was applied to the sclera 1 mm behind the limbus to acquire real-time video. Image acquisition was performed at 15-degree intervals along the limbal circumference to quantify regional flow variation in human eyes. Results: Vascular structures were visualized in whole human eyes without processing. Schlemm's canal was visualized only after a scleral flap was created. Fluorescent signal intensity and vessel diameter variation were observed along the limbal circumference, with the inferior quadrant having a statistically higher fluorescein signal compared to the other quadrants in human eyes ( P < 0.05). Conclusion: This study demonstrates for the first time that the fiber-optic CLE platform can visualize the episcleral vasculature with high resolution ex-vivo with minimal tissue manipulation. Intravascular signal intensities and vessel diameters were acquired in real-time; such information can help select target areas for minimally invasive glaucoma surgery (MIGS) to achieve greater intraocular pressure reduction.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2008-322X
Relation: https://doaj.org/toc/2008-322X
DOI: 10.18502/jovr.v14i3.4783
URL الوصول: https://doaj.org/article/95fadd2f5b6548fd96dd36762834bc12
رقم الأكسشن: edsdoj.95fadd2f5b6548fd96dd36762834bc12
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:2008322X
DOI:10.18502/jovr.v14i3.4783