دورية أكاديمية

Non-contact wide-field viewing system-assisted scleral buckling surgery for retinal detachment in silicone oil-filled eyes

التفاصيل البيبلوغرافية
العنوان: Non-contact wide-field viewing system-assisted scleral buckling surgery for retinal detachment in silicone oil-filled eyes
المؤلفون: Su-Lan Wu, Yi-Qi Chen, Li-Jun Shen, Jian-Bo Mao, Li Lin, Ji-Wei Tao, Huan Chen, Shi-An Zhang, Jia-Feng Yu, Chen-Xi Wang
المصدر: International Journal of Ophthalmology, Vol 17, Iss 4, Pp 761-766 (2024)
بيانات النشر: Press of International Journal of Ophthalmology (IJO PRESS), 2024.
سنة النشر: 2024
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: non-contact wide-field viewing system, scleral buckling, silicone oil-filled, retinal detachment, Ophthalmology, RE1-994
الوصف: AIM: To evaluate scleral buckling (SB) surgery using a non-contact wide-field viewing system and 23-gauge intraocular illumination for the treatment of rhegmatogenous retinal detachment in silicone oil (SO)-filled eyes. METHODS: Totally 9 patients (9 eyes) with retinal detachment in SO-filled eyes were retrospectively analyzed. All patients underwent non-contact wide-field viewing system-assisted buckling surgery with 23-gauge intraocular illumination. SO was removed at an appropriate time based on recovery. The patients were followed up for at least 3mo after SO removal. Retinal reattachment, complications, visual acuity and intraocular pressure (IOP) before and after surgery were observed. RESULTS: Patients were followed up for a mean of 8.22mo (3-22mo) after SO removal. All patients had retinal reattachment. At the final follow-up, visual acuity showed improvement for 8 patients, and no change for 1 patient. The IOP was high in 3 patients before surgery, but it stabilized after treatment; it was not affected in the other patients. None of the patients had infections, hemorrhage, anterior ischemia, or any other complication. CONCLUSION: This new non-contact wide-field viewing system-assisted SB surgery with 23-gauge intraocular illumination is effective and safe for retinal detachment in SO-filled eyes.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2222-3959
2227-4898
Relation: http://ies.ijo.cn/en_publish/2024/4/20240421.pdf; https://doaj.org/toc/2222-3959; https://doaj.org/toc/2227-4898
DOI: 10.18240/ijo.2024.04.21
URL الوصول: https://doaj.org/article/96b0149f19b54d03a7a634645e94f951
رقم الأكسشن: edsdoj.96b0149f19b54d03a7a634645e94f951
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22223959
22274898
DOI:10.18240/ijo.2024.04.21