دورية أكاديمية

Comparative evaluation of the efficacy of diode laser, EndoActivator, passive ultrasonic irrigant, and manual irrigation activation systems in debridement of root canal isthmus: An in vitro study

التفاصيل البيبلوغرافية
العنوان: Comparative evaluation of the efficacy of diode laser, EndoActivator, passive ultrasonic irrigant, and manual irrigation activation systems in debridement of root canal isthmus: An in vitro study
المؤلفون: Arun Kurian Varghese, S V Satish, Basavana Gowda, Roshan Uthappa, Ashwini M Patil
المصدر: Endodontology, Vol 34, Iss 1, Pp 27-31 (2022)
بيانات النشر: Wolters Kluwer Medknow Publications, 2022.
سنة النشر: 2022
المجموعة: LCC:Dentistry
مصطلحات موضوعية: diode laser, endoactivator, isthmus, root canal irrigation, ultrasonics, Dentistry, RK1-715
الوصف: Objective: This study aimed to compare the efficacy of diode laser, EndoActivator, passive ultrasonic irrigation (PUI), and manual dynamic activation (MDA) in the debridement of root canal isthmus using a stereomicroscope. Materials and Methods: A total of 65 extracted mandibular first molars were selected for the study. The access cavity preparation was done and the working length was determined. All teeth were prepared using ProTaper rotary system up to F2. The samples were randomly divided into five groups (n = 13) used in the study. Group 1: Diode laser (n = 13): samples were irrigated using a diode laser having a wavelength of 980 nm. Group 2: EndoActivator (n = 13): the samples were irrigated using EndoActivator sonic device. Group 3: PUI (n = 13): samples were irrigated using an ultrasonic device. Group 4: MDA (n = 13): samples were irrigated manually by placing a master gutta-percha cone of F2 size. Group 5: Conventional needle irrigation (n = 13): no activation of irrigant. Following irrigant activation, the mesial roots were sectioned 4 mm from the apex and the isthmus cleanliness was observed under a stereomicroscope at ×20. Statistical analysis was done using ANOVA and post hoc Tukey's test. Results: EndoActivator showed the least amount of debris when compared to diode laser, passive ultrasonic irrigant, and MDA. MDA showed more amount of debris at the isthmus level. Conclusion: EndoActivator showed the least amount of debris at the isthmus level of mandibular molars when compared to diode laser, passive ultrasonic irrigant, and MDA.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0970-7212
Relation: http://www.endodontologyonweb.org/article.asp?issn=0970-7212;year=2022;volume=34;issue=1;spage=27;epage=31;aulast=Varghese; https://doaj.org/toc/0970-7212
DOI: 10.4103/endo.endo_173_21
URL الوصول: https://doaj.org/article/972af7d899674cea9c83f73a97aa63ae
رقم الأكسشن: edsdoj.972af7d899674cea9c83f73a97aa63ae
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09707212
DOI:10.4103/endo.endo_173_21