دورية أكاديمية
Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system.
العنوان: | Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system. |
---|---|
المؤلفون: | Kazuno Negishi, Sachiko Masui, Hidemasa Torii, Yasuyo Nishi, Kazuo Tsubota |
المصدر: | PLoS ONE, Vol 15, Iss 9, p e0238366 (2020) |
بيانات النشر: | Public Library of Science (PLoS), 2020. |
سنة النشر: | 2020 |
المجموعة: | LCC:Medicine LCC:Science |
مصطلحات موضوعية: | Medicine, Science |
الوصف: | PurposeTo investigate refractive stability and characterize corneal incision repair up to 3 months after implantation of a new hydrophobic acrylic intraocular lens (IOL) with hydroxyethylmethacrylate using a new automated IOL delivery system.MethodsThis prospective case series included 50 eyes of 50 patients undergoing phacoemulsification and implantation of the Clareon® CNA0T0 IOL using the AutonoMe® automated delivery system in the Department of Ophthalmology, Keio University School of Medicine. The clinical data were collected from 46 eyes of 46 patients preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. Endothelial-side incision gaping, posterior incision retraction, and Descemet's membrane detachment were recorded as present or absent using anterior-segment optical coherence tomography postoperatively.ResultsThe uncorrected distance and corrected distance visual acuities improved and stabilized 1 week postoperatively. The anterior chamber depth was stable from 1 week postoperatively. The subjective refraction was stable from 1 day postoperatively. Descemet's membrane detachments and endothelial-side wound gaping were seen in 19 (41.3%) eyes and 34 (73.9%) eyes 1 day postoperatively and decreased gradually. Posterior incision retraction was seen in eight eyes (17.4%) on day 1 and increased to 19 eyes (41.3%) 3 months postoperatively.ConclusionsThe Clareon IOL had excellent refractive stability from day 1 postoperatively. The AutonoMe automated delivery system enables safe IOL implantation through a 2.4-mm corneal incision, although the wound required longer than 1 month to heal postoperatively. |
نوع الوثيقة: | article |
وصف الملف: | electronic resource |
اللغة: | English |
تدمد: | 1932-6203 |
Relation: | https://doaj.org/toc/1932-6203 |
DOI: | 10.1371/journal.pone.0238366 |
URL الوصول: | https://doaj.org/article/9a58a0879cbf4b99a3f5e15615fbcafb |
رقم الأكسشن: | edsdoj.9a58a0879cbf4b99a3f5e15615fbcafb |
قاعدة البيانات: | Directory of Open Access Journals |
تدمد: | 19326203 |
---|---|
DOI: | 10.1371/journal.pone.0238366 |