دورية أكاديمية

Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system.

التفاصيل البيبلوغرافية
العنوان: Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system.
المؤلفون: Kazuno Negishi, Sachiko Masui, Hidemasa Torii, Yasuyo Nishi, Kazuo Tsubota
المصدر: PLoS ONE, Vol 15, Iss 9, p e0238366 (2020)
بيانات النشر: Public Library of Science (PLoS), 2020.
سنة النشر: 2020
المجموعة: LCC:Medicine
LCC:Science
مصطلحات موضوعية: Medicine, Science
الوصف: PurposeTo investigate refractive stability and characterize corneal incision repair up to 3 months after implantation of a new hydrophobic acrylic intraocular lens (IOL) with hydroxyethylmethacrylate using a new automated IOL delivery system.MethodsThis prospective case series included 50 eyes of 50 patients undergoing phacoemulsification and implantation of the Clareon® CNA0T0 IOL using the AutonoMe® automated delivery system in the Department of Ophthalmology, Keio University School of Medicine. The clinical data were collected from 46 eyes of 46 patients preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. Endothelial-side incision gaping, posterior incision retraction, and Descemet's membrane detachment were recorded as present or absent using anterior-segment optical coherence tomography postoperatively.ResultsThe uncorrected distance and corrected distance visual acuities improved and stabilized 1 week postoperatively. The anterior chamber depth was stable from 1 week postoperatively. The subjective refraction was stable from 1 day postoperatively. Descemet's membrane detachments and endothelial-side wound gaping were seen in 19 (41.3%) eyes and 34 (73.9%) eyes 1 day postoperatively and decreased gradually. Posterior incision retraction was seen in eight eyes (17.4%) on day 1 and increased to 19 eyes (41.3%) 3 months postoperatively.ConclusionsThe Clareon IOL had excellent refractive stability from day 1 postoperatively. The AutonoMe automated delivery system enables safe IOL implantation through a 2.4-mm corneal incision, although the wound required longer than 1 month to heal postoperatively.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1932-6203
Relation: https://doaj.org/toc/1932-6203
DOI: 10.1371/journal.pone.0238366
URL الوصول: https://doaj.org/article/9a58a0879cbf4b99a3f5e15615fbcafb
رقم الأكسشن: edsdoj.9a58a0879cbf4b99a3f5e15615fbcafb
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19326203
DOI:10.1371/journal.pone.0238366