دورية أكاديمية

Effect of nocturnal EPAP titration to abolish tidal expiratory flow limitation in COPD patients with chronic hypercapnia: a randomized, cross-over pilot study

التفاصيل البيبلوغرافية
العنوان: Effect of nocturnal EPAP titration to abolish tidal expiratory flow limitation in COPD patients with chronic hypercapnia: a randomized, cross-over pilot study
المؤلفون: Emanuela Zannin, Ilaria Milesi, Roberto Porta, Simona Cacciatore, Luca Barbano, R. Trentin, Francesco Fanfulla, Michele Vitacca, Raffaele L. Dellacà
المصدر: Respiratory Research, Vol 21, Iss 1, Pp 1-7 (2020)
بيانات النشر: BMC, 2020.
سنة النشر: 2020
المجموعة: LCC:Diseases of the respiratory system
مصطلحات موضوعية: Non-invasive ventilation, Chronic obstructive pulmonary disease, Forced oscillation technique, Intrinsic PEEP, Diseases of the respiratory system, RC705-779
الوصف: Abstract Background Tidal expiratory flow limitation (EFLT) promotes intrinsic PEEP (PEEPi) in patients with chronic obstructive pulmonary disease (COPD). Applying non-invasive ventilation (NIV) with an expiratory positive airway pressure (EPAP) matching PEEPi improves gas exchange, reduces work of breathing and ineffective efforts. We aimed to evaluate the effects of a novel NIV mode that continuously adjusts EPAP to the minimum level that abolishes EFLT. Methods This prospective, cross-over, open-label study randomized patients to one night of fixed-EPAP and one night of EFLT-abolishing-EPAP. The primary outcome was transcutaneous carbon dioxide pressure (PtcCO2). Secondary outcomes were: peripheral oxygen saturation (SpO2), frequency of ineffective efforts, breathing patterns and oscillatory mechanics. Results We screened 36 patients and included 12 in the analysis (age 72 ± 8 years, FEV1 38 ± 14%Pred). The median EPAP did not differ between the EFLT-abolishing-EPAP and the fixed-EPAP night (median (IQR) = 7.0 (6.0, 8.8) cmH2O during night vs 7.5 (6.5, 10.5) cmH2O, p = 0.365). We found no differences in mean PtcCO2 (44.9 (41.6, 57.2) mmHg vs 54.5 (51.1, 59.0), p = 0.365), the percentage of night time with PtcCO2 > 45 mm Hg was lower (62(8,100)% vs 98(94,100)%, p = 0.031) and ineffective efforts were fewer (126(93,205) vs 261(205,351) events/hour, p = 0.003) during the EFLT-abolishing-EPAP than during the fixed-EPAP night. We found no differences in oxygen saturation and lung mechanics between nights. Conclusion An adaptive ventilation mode targeted to abolish EFLT has the potential to reduce hypercapnia and ineffective efforts in stable COPD patients receiving nocturnal NIV. Trial registration: ClicalTrials.gov, NCT04497090. Registered 29 July 2020—Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04497090 .
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1465-993X
Relation: http://link.springer.com/article/10.1186/s12931-020-01567-x; https://doaj.org/toc/1465-993X
DOI: 10.1186/s12931-020-01567-x
URL الوصول: https://doaj.org/article/9d60739dde2f46fb945bb6ffb4d1650a
رقم الأكسشن: edsdoj.9d60739dde2f46fb945bb6ffb4d1650a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:1465993X
DOI:10.1186/s12931-020-01567-x