الوصف: Aim: To compare the dosimetric advantages and disadvantages between hybrid intensity-modulated radiation therapy (h-IMRT) and the volumetric modulated arc therapy (VMAT) technique in hypofractionated whole-breast irradiation (HF-WBI) for early-stage breast cancer (BC). Methods: The dose distribution of h-IMRT and VMAT plans was compared in 20 breast cancer patients. This comparison included evaluation of dosimetric parameters using dose volume histograms (DVHs) for the planning target volume (PTV) and organs-at-risk (OARs). Additionally, the study examined the normal tissue complication probability (NTCP), the second cancer complication probability (SCCP) and the tumor control probability (TCP) based on different models. Results: Significant differences were detected between the two plans, in terms of Machine units (MUs), the control points, 95 % volume (V95 %), dose homogeneity index (DHI) and conformity index (CI). The endpoint of grade II radiation pneumonitis and cardiac death due to ischemic heart disease were assessed. In h-IMRT plan, the NTCP values were marginally lower for radiation pneumonitis and slightly higher for cardiac death compared to VMAT plan, as determined by the Lyman–Kutcher–Burman model. The Schneider model was employed to predict the SCCP for both the bilateral lungs and contralateral breast, the results demonstrate that the h-IMRT plan outperforms the VMAT plan, with statistical significance. Additionally, the LQ-Poisson model was employed to forecast the TCP of the PTV, showing that the h-IMRT plan outperformed the VMAT plan (P > 0.05). Conclusion: The h-IMRT technique, offering superior dose coverage and better therapeutic efficacy with fewer side effects as calculated by models, is more suitable for HF-WBI compared to the VMAT technique.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1936-5233
Relation: http://www.sciencedirect.com/science/article/pii/S1936523324001396; https://doaj.org/toc/1936-5233
DOI: 10.1016/j.tranon.2024.102012
URL الوصول: https://doaj.org/article/9d9f6f061bb547ceb04e36cf16bf7f15
رقم الأكسشن: edsdoj.9d9f6f061bb547ceb04e36cf16bf7f15
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:19365233
DOI:10.1016/j.tranon.2024.102012