دورية أكاديمية

Development of a Rapid and Fully Automated Multiplex Real-Time PCR Assay for Identification and Differentiation of Vibrio cholerae and Vibrio parahaemolyticus on the BD MAX Platform

التفاصيل البيبلوغرافية
العنوان: Development of a Rapid and Fully Automated Multiplex Real-Time PCR Assay for Identification and Differentiation of Vibrio cholerae and Vibrio parahaemolyticus on the BD MAX Platform
المؤلفون: Zhenpeng Li, Hongxia Guan, Wei Wang, He Gao, Weihong Feng, Jie Li, Baowei Diao, Hongqun Zhao, Biao Kan, Jingyun Zhang
المصدر: Frontiers in Cellular and Infection Microbiology, Vol 11 (2021)
بيانات النشر: Frontiers Media S.A., 2021.
سنة النشر: 2021
المجموعة: LCC:Microbiology
مصطلحات موضوعية: Vibrio cholerae, Vibrio parahaemolyticus, multiplex, real-time PCR, BD MAX, Microbiology, QR1-502
الوصف: Vibrio cholerae and Vibrio parahaemolyticus are common diarrheal pathogens of great public health concern. A multiplex TaqMan-based real-time PCR assay was developed on the BD MAX platform; this assay can simultaneously detect and differentiate V. cholerae and V. parahaemolyticus directly from human fecal specimens. The assay includes two reactions. One reaction, BDM-VC, targets the gene ompW, the cholera toxin (CT) coding gene ctxA, the O1 serogroup specific gene rfbN, and the O139 serogroup specific gene wbfR of V. cholerae. The other, BDM-VP, targets the gene toxR and the toxin coding genes tdh and trh of V. parahaemolyticus. In addition, each reaction contains a sample process control. When evaluated with spiked stool samples, the detection limit of the BD MAX assay was 195–780 CFU/ml for V. cholerae and 46–184 CFU/ml for V. parahaemolyticus, and the amplification efficiency of all genes was between 95 and 115%. The assay showed 100% analytical specificity, using 63 isolates. The BD MAX assay was evaluated for its performance compared with conventional real-time PCR after automated DNA extraction steps, using 164 retrospective stool samples. The overall percent agreement between the BD MAX assay and real-time PCR was ≥ 98.8%; the positive percent agreement was 85.7% for ompW, 100% for toxR/tdh, and lower (66.7%) for trh because of a false negative. This is the first report to evaluate the usage of the BD MAX open system in detection and differentiation of V. cholerae and V. parahaemolyticus directly from human samples.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2235-2988
Relation: https://www.frontiersin.org/articles/10.3389/fcimb.2021.639473/full; https://doaj.org/toc/2235-2988
DOI: 10.3389/fcimb.2021.639473
URL الوصول: https://doaj.org/article/9ee208e3b5c3494ca53b77cf2bde91cf
رقم الأكسشن: edsdoj.9ee208e3b5c3494ca53b77cf2bde91cf
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22352988
DOI:10.3389/fcimb.2021.639473