المؤلفون: Abu-Samah A, Knopp JL, Abdul Razak NN, Razak AA, Jamaludin UK, Mohamad Suhaimi F, Md Ralib A, Mat Nor MB, Chase JG, Pretty CG
المصدر: Medical Devices: Evidence and Research, Vol Volume 12, Pp 215-226 (2019)
بيانات النشر: Dove Medical Press, 2019.
سنة النشر: 2019
المجموعة: LCC:Medical technology
مصطلحات موضوعية: Glycemic control, Intensive care unit, Model-based control, Pilot trial, Malaysian hospital, Medical technology, R855-855.5
الوصف: Asma Abu-Samah,1 Jennifer Launa Knopp,2 Normy Norfiza Abdul Razak,3 Athirah Abdul Razak,3 Ummu Kulthum Jamaludin,3 Fatanah Mohamad Suhaimi,4 Azrina Md Ralib,5 Mohd Basri Mat Nor,6 James Geoffrey Chase,2 Christopher Grant Pretty21Institute of Energy Infrastructure, Universiti Tenaga Nasional, Kajang, 43000, Malaysia; 2Department of Mechanical Engineering, University of Canterbury, Christchurch, 8041, New Zealand; 3College of Engineering, Universiti Tenaga Nasional, Kajang, 43000, Malaysia; 4Faculty of Mechanical Engineering, Universiti Malaysia Pahang, Pekan, 26600, Malaysia; 5Advanced Medical and Dental Institute, Universiti Sains Islam Malaysia, Kepala Batas, 13200, Malaysia; 6Kulliyah of Medicine, International Islamic University Malaysia, Kuantan, 25200, MalaysiaBackground: Stress-induced hyperglycemia is common in critically ill patients. A few forms of model-based glycemic control have been introduced to reduce this phenomena and among them is the automated STAR protocol which has been used in the Christchurch and Gyulá hospitals’ intensive care units (ICUs) since 2010.Methods: This article presents the pilot trial assessment of STAR protocol which has been implemented in the International Islamic University Malaysia Medical Centre (IIUMMC) Hospital ICU since December 2017. One hundred and forty-two patients who received STAR treatment for more than 20 hours were used in the assessment. The initial results are presented to discuss the ability to adopt and adapt the model-based control framework in a Malaysian environment by analyzing its performance and safety.Results: Overall, 60.7% of blood glucose measurements were in the target band. Only 0.78% and 0.02% of cohort measurements were below 4.0 mmol/L and 2.2 mmol/L (the limitsfor mild and severe hypoglycemia, respectively). Treatment preference-wise, the clinical staff were favorable of longer intervention options when available. However, 1 hourly treatments were still used in 73.7% of cases.Conclusion: The protocol succeeded in achieving patient-specific glycemic control while maintaining safety and was trusted by nurses to reduce workload. Its lower performance results, however, give the indication for modification in some of the control settings to better fit the Malaysian environment.Keywords: glycemic control, intensive care unit, model-based control, pilot trial, Malaysian hospital
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1179-1470
Relation: https://www.dovepress.com/model-based-glycemic-control-in-a-malaysian-intensive-care-unit-perfor-peer-reviewed-article-MDER; https://doaj.org/toc/1179-1470
URL الوصول: https://doaj.org/article/b30cf322370d4e62a31ad3d4c7d83503
رقم الأكسشن: edsdoj.b30cf322370d4e62a31ad3d4c7d83503
قاعدة البيانات: Directory of Open Access Journals