دورية أكاديمية

Validation of the RBP‐9801 oscillometric blood pressure monitor in the general population according to the association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard

التفاصيل البيبلوغرافية
العنوان: Validation of the RBP‐9801 oscillometric blood pressure monitor in the general population according to the association for the Advancement of Medical Instrumentation/European Society of Hypertension/ International Organization for Standardization Universal Standard
المؤلفون: Shijie Yang, Zhanyang Zhou, Huanhuan Miao, Qiong Zhou, Mei Zhai, Yuqing Zhang
المصدر: The Journal of Clinical Hypertension, Vol 26, Iss 6, Pp 703-707 (2024)
بيانات النشر: Wiley, 2024.
سنة النشر: 2024
المجموعة: LCC:Diseases of the circulatory (Cardiovascular) system
مصطلحات موضوعية: accuracy, blood pressure monitoring, ISO protocol, Validation, Diseases of the circulatory (Cardiovascular) system, RC666-701
الوصف: Abstract The aim of this study was to evaluate the accuracy of the single upper‐arm cuff oscillometric blood pressure (BP) monitor RBP‐9801 developed for office and home BP measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060–2:2018). Subjects were recruited to fulfil the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. A total of 105 subjects were recruited and 85 were analyzed. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.3 ± 6.4/3.1 ± 5.8 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.24/5.03 mmHg (systolic/diastolic). The conclusion is that the RBP‐9801 oscillometric device for office and home BP measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060–2:2018) in the general population and can be recommended for clinic and self‐use at home.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1751-7176
1524-6175
67144349
Relation: https://doaj.org/toc/1524-6175; https://doaj.org/toc/1751-7176
DOI: 10.1111/jch.14812
URL الوصول: https://doaj.org/article/b4c4519ff67144349f4f06d11cc58193
رقم الأكسشن: edsdoj.b4c4519ff67144349f4f06d11cc58193
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:17517176
15246175
67144349
DOI:10.1111/jch.14812