دورية أكاديمية

A Rotary Spacer System for Energy-Efficient Membrane Fouling Control in Oil/Water Emulsion Filtration

التفاصيل البيبلوغرافية
العنوان: A Rotary Spacer System for Energy-Efficient Membrane Fouling Control in Oil/Water Emulsion Filtration
المؤلفون: Normi Izati Mat Nawi, Afiq Mohd Lazis, Aulia Rahma, Muthia Elma, Muhammad Roil Bilad, Nik Abdul Hadi Md Nordin, Mohd Dzul Hakim Wirzal, Norazanita Shamsuddin, Hazwani Suhaimi, Norhaniza Yusof
المصدر: Membranes, Vol 12, Iss 6, p 554 (2022)
بيانات النشر: MDPI AG, 2022.
سنة النشر: 2022
المجموعة: LCC:Chemical technology
LCC:Chemical engineering
مصطلحات موضوعية: membrane fouling, dynamic membrane filtration, rotating spacer, oil/water emulsion, Chemical technology, TP1-1185, Chemical engineering, TP155-156
الوصف: Membrane fouling deteriorates membrane filtration performances. Hence, mitigating membrane fouling is the key factor in sustaining the membrane process, particularly when treating fouling-prone feed, such as oil/water emulsions. The use of spacers has been expanded in the membrane module system, including for membrane fouling control. This study proposed a rotating spacer system to ameliorate membrane fouling issues when treating an oil/water emulsion. The system’s effectiveness was assessed by investigating the effect of rotating speed and membrane-to-disk gap on the hydraulic performance and the energy input and through computational fluid dynamics (CFD) simulation. The results showed that the newly developed rotary spacer system was effective and energy-efficient for fouling control. The CFD simulation results proved that the spacer rotations induced secondary flow near the membrane surface and imposed shear rate and lift force to exert fouling control. Increasing the rotation speed to an average linear velocity of 0.44 m/s increased the permeability from 126.8 ± 2.1 to 175.5 ± 2.7 Lm−2h−1bar−1. The system showed better performance at a lower spacer-to-membrane gap, in which increasing the gap from 0.5 to 2.0 cm lowered the permeability from 175.5 ± 2.7 to 126.7 ± 2.0 Lm−2h−1bar−1. Interestingly, the rotary system showed a low energy input of 1.08 to 4.08 × 10−3 kWhm−3 permeate when run at linear velocities of 0.27 to 0.44 ms−1. Overall, the findings suggest the competitiveness of the rotary spacer system as a method for membrane fouling control.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2077-0375
Relation: https://www.mdpi.com/2077-0375/12/6/554; https://doaj.org/toc/2077-0375
DOI: 10.3390/membranes12060554
URL الوصول: https://doaj.org/article/eb5a57914d8b4748bf4f0cb3992eea2b
رقم الأكسشن: edsdoj.b5a57914d8b4748bf4f0cb3992eea2b
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20770375
DOI:10.3390/membranes12060554