Multi-Probe RFA vs. Single-Probe MWA in an Ex Vivo Bovine Liver Model: Comparison of Volume and Shape of Coagulation Zones

التفاصيل البيبلوغرافية
العنوان: Multi-Probe RFA vs. Single-Probe MWA in an Ex Vivo Bovine Liver Model: Comparison of Volume and Shape of Coagulation Zones
المؤلفون: Gregor Laimer, Michael Bauer, Yannick Scharll, Peter Schullian, Reto Bale
المصدر: Biology, Vol 12, Iss 8, p 1103 (2023)
بيانات النشر: MDPI AG, 2023.
سنة النشر: 2023
المجموعة: LCC:Biology (General)
مصطلحات موضوعية: radiofrequency ablation, ablation techniques, liver, Biology (General), QH301-705.5
الوصف: Objectives: To compare the volumes and shapes of the coagulation zone (CZ) of a multi-probe RFA system (three RFA electrodes) and a single-probe MWA system from the same vendor in an ex vivo bovine liver model. Material & Methods: A total of 48 CZs were obtained in bovine liver specimens with three different ablation system configurations (single-probe MWA vs. multi-probe RFA with 20 mm inter-probe distance [confluent CZ] vs. multi-probe RFA with 50 mm inter-probe distance [three individual CZs]) at 4, 6, 8, and 10 min ablation time using a fixed ablation protocol. Ablation diameters were measured and ellipticity indices (EIs) and volumes calculated. Calculations for all systems/configurations were compared. Results: Volumes and diameters increased with ablation time for all configurations. At 4 and 6 min ablation time volumes obtained with the RFA 50 mm setup, and at 8 and 10 min with the RFA 20 mm setup were the largest at 26.5 ± 4.1 mL, 38.1 ± 5.8 mL, 46.3 ± 4.9 mL, 48.4 ± 7.3 mL, respectively. The single-probe MWA could not reach the volumes of the RFA setups for any of the ablation times evaluated. EI were very similar and almost round for RFA 20 mm and single-probe MWA, and differed significantly to the more ovoid ones for the RFA 50 mm configuration. Conclusions: The multi-probe RFA system employing three electrodes achieved significantly larger ablation volumes in both configurations (confluent CZ and three individual CZs) per time as compared with a single-probe MWA system in this ex vivo bovine liver model.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2079-7737
Relation: https://www.mdpi.com/2079-7737/12/8/1103; https://doaj.org/toc/2079-7737
DOI: 10.3390/biology12081103
URL الوصول: https://doaj.org/article/ba8cba45c6c74f90adbec1f7d10f5aa4
رقم الأكسشن: edsdoj.ba8cba45c6c74f90adbec1f7d10f5aa4
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:20797737
DOI:10.3390/biology12081103