دورية أكاديمية

Monte Carlo Simulation and Experimental Validation for Radiation Protection with Multiple Complex Source Terms and Deep Penetration for a Radioactive Liquid Waste Cementation Facility

التفاصيل البيبلوغرافية
العنوان: Monte Carlo Simulation and Experimental Validation for Radiation Protection with Multiple Complex Source Terms and Deep Penetration for a Radioactive Liquid Waste Cementation Facility
المؤلفون: Wenqian Li, Xuegang Liu, Sheng Fang, Xueliang Fu, Kaiqiang Guo
المصدر: Science and Technology of Nuclear Installations, Vol 2020 (2020)
بيانات النشر: Wiley, 2020.
سنة النشر: 2020
المجموعة: LCC:Electrical engineering. Electronics. Nuclear engineering
مصطلحات موضوعية: Electrical engineering. Electronics. Nuclear engineering, TK1-9971
الوصف: A new radioactive liquid waste cementation facility was under commissioning recently in the Institute of Nuclear and New Energy Technology of Tsinghua University, which is designed to simultaneously process multiple intermediate-level radioactive waste drums. Therefore, the multiple volume sources and the scattering effect becomes a key issue in its radiation protection. For this purpose, the Monte Carlo program FLUKA code and experimental measurement were both adopted. In the FLUKA simulation, five different scenarios were considered, i.e., one drum, two drums, four drums, six drums, and eight drums. For the multiple volume sources, the source subroutine code of FLUKA was rewritten to realize the sampling. The complex shielding also leads to a deep penetration problem; hence, the optimization algorithm and variance reduction techniques were adopted. During the measurement, two scenarios, outdoor and indoor, were carried out separately representing the dose field when only one drum is considered and when the scattering effect is considered. A comparison between the experiments and calculations shows very good agreement. From both of the Monte Carlo simulation and the experimental measurement, it can be drawn that, in the horizontal direction, with the increase of the drum number, the dose rate increases very little, while in the vertical direction, the increase of the dose rate is very obvious with the increase of the drum number. The complicated source term sampling methods, the optimization algorithm and variance reduction techniques, and the experimental verification can provide valuable references for the similar scattering problem in radiation protection and shielding design.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1687-6075
1687-6083
Relation: https://doaj.org/toc/1687-6075; https://doaj.org/toc/1687-6083
DOI: 10.1155/2020/8819794
URL الوصول: https://doaj.org/article/ebcd7d4ea48741948ea2980c960c2183
رقم الأكسشن: edsdoj.bcd7d4ea48741948ea2980c960c2183
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:16876075
16876083
DOI:10.1155/2020/8819794