دورية أكاديمية

Quality assurance process within the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial for the fusion of electroanatomical mapping and radiotherapy planning imaging data in cardiac radioablation

التفاصيل البيبلوغرافية
العنوان: Quality assurance process within the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial for the fusion of electroanatomical mapping and radiotherapy planning imaging data in cardiac radioablation
المؤلفون: Michael Mayinger, Judit Boda-Heggemann, Felix Mehrhof, David Krug, Stephan Hohmann, Jingyang Xie, Stefanie Ehrbar, Boldizsar Kovacs, Roland Merten, Melanie Grehn, Adrian Zaman, Jens Fleckenstein, Lena Kaestner, Daniel Buergy, Boris Rudic, Anne Kluge, Leif-Hendrik Boldt, Jürgen Dunst, Hendrik Bonnemeier, Ardan M. Saguner, Nicolaus Andratschke, Oliver Blanck, Achim Schweikard
المصدر: Physics and Imaging in Radiation Oncology, Vol 25, Iss , Pp 100406- (2023)
بيانات النشر: Elsevier, 2023.
سنة النشر: 2023
المجموعة: LCC:Medical physics. Medical radiology. Nuclear medicine
LCC:Neoplasms. Tumors. Oncology. Including cancer and carcinogens
مصطلحات موضوعية: Electroanatomical mapping, Radiotherapy planning, Cardiac radioablation, Quality assurance, CARDIO-RT, Medical physics. Medical radiology. Nuclear medicine, R895-920, Neoplasms. Tumors. Oncology. Including cancer and carcinogens, RC254-282
الوصف: A novel quality assurance process for electroanatomical mapping (EAM)-to-radiotherapy planning imaging (RTPI) target transport was assessed within the multi-center multi-platform framework of the RAdiosurgery for VENtricular TAchycardia (RAVENTA) trial. A stand-alone software (CARDIO-RT) was developed to enable platform independent registration of EAM and RTPI of the left ventricle (LV), based on pre-generated radiotherapy contours (RTC). LV-RTC were automatically segmented into the American-Heart-Association 17-segment-model and a manual 3D-3D method based on EAM 3D-geometry data and a semi-automated 2D-3D method based on EAM screenshot projections were developed. The quality of substrate transfer was evaluated in five clinical cases and the structural analyses showed substantial differences between manual target transfer and target transport using CARDIO-RT.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2405-6316
Relation: http://www.sciencedirect.com/science/article/pii/S240563162200104X; https://doaj.org/toc/2405-6316
DOI: 10.1016/j.phro.2022.12.003
URL الوصول: https://doaj.org/article/bfc6d9c159f24b68b3d582b3d1d302f3
رقم الأكسشن: edsdoj.bfc6d9c159f24b68b3d582b3d1d302f3
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:24056316
DOI:10.1016/j.phro.2022.12.003