العنوان: Comparison of three fundus inspection methods during phacoemulsification in diabetic white cataract
المؤلفون: Shu Su, Jian Wu, Min Ji, Yu Guan, Yao Shen, Huai-Jin Guan
المصدر: International Journal of Ophthalmology, Vol 16, Iss 11, Pp 1782-1788 (2023)
بيانات النشر: Press of International Journal of Ophthalmology (IJO PRESS), 2023.
سنة النشر: 2023
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: diabetic white cataract, fundus inspection, phacoemulsification, diabetic retinopathy, Ophthalmology, RE1-994
الوصف: AIM: To investigate whether Wild Field Imaging System (WFIS SW-8000), 25G endoilluminator, and intraoperative optical coherence tomography (iOCT) can perform real-time screening and diagnosing in patients with suspicious diabetic retinopathy (DR) during phacoemulsification, especially in cases of white cataract. METHODS: A cross-sectional study was carried out. A total of 204 dense diabetic cataractous eyes of 204 patients with suspected DR treated from April 2020 to March 2021 were included. Phacoemulsification combined with intraocular lens implantation was performed. Following the removal of the lens opacity, the 25G endo-illuminator, fundus photography, and iOCT were performed successively. Optical coherence tomography (OCT) and/or fundus fluorescein angiography (FFA) were used to verify the fundus findings postoperatively. Intraoperative and postoperative results were compared to verify the accuracy of intraoperative diagnosis in each group. RESULTS: Intraoperative and postoperative examinations revealed 58 and 62 eyes with DR, respectively (positive rate, 28.43% and 30.39%, respectively). During the phacoemulsification, WFIS SW-8000 detected 44 eyes with DR (the detection rate, 70.97%); 25G endo-illuminator found 56 eyes with DR (the detection rate, 90.32%); iOCT found 46 eyes with DR (the detection rate, 74.19%); and 58 eyes with DR were found by combining the three methods (the detection rate, 93.55%). There were statistically significant differences in the diagnostic sensitivity for DR among the methods (χ2=16.36, P=0.001). CONCLUSION: WFIS SW-8000, 25G endo-illuminator, iOCT, and especially their combination can be used to inspect the fundus and detect DR intraoperatively; they are helpful for the timely diagnosis and treatment of DR in patients with dense cataract.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2222-3959
2227-4898
Relation: http://ies.ijo.cn/en_publish/2023/11/20231107.pdf; https://doaj.org/toc/2222-3959; https://doaj.org/toc/2227-4898
DOI: 10.18240/ijo.2023.11.07
URL الوصول: https://doaj.org/article/f0cedb4defb7415092256367388fdbfe
رقم الأكسشن: edsdoj.f0cedb4defb7415092256367388fdbfe
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22223959
22274898
DOI:10.18240/ijo.2023.11.07