دورية أكاديمية

Predictability of Residual Postoperative Astigmatism After Implantation of a Toric Intraocular Lens Using Two Different Calculators

التفاصيل البيبلوغرافية
العنوان: Predictability of Residual Postoperative Astigmatism After Implantation of a Toric Intraocular Lens Using Two Different Calculators
المؤلفون: Pantanelli SM, Kansara N, Smits G
المصدر: Clinical Ophthalmology, Vol Volume 14, Pp 3627-3634 (2020)
بيانات النشر: Dove Medical Press, 2020.
سنة النشر: 2020
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: cataract, toric, intraocular lens power, astigmatism, calculators, evo, Ophthalmology, RE1-994
الوصف: Seth M Pantanelli,1 Neal Kansara,1 Gerard Smits2 1Department of Ophthalmology, Penn State College of Medicine, Hershey, PA, USA; 2Computer and Statistical Consultants Incorporated, Santa Barbara, CA, USACorrespondence: Seth M PantanelliDepartment of Ophthalmology, Penn State College of Medicine, 500 University Drive; HU19, Hershey, PA 17033-0850, USATel +1 717-531-5690Fax +1 717-531-5009Email spantanelli@pennstatehealth.psu.eduPurpose: To compare predictability of postoperative refractive astigmatism (RA) using the Emmetropic Verifying Optical (EVO) Toric Formula v2.0 to one that accounts only for anterior corneal astigmatism.Methods: This is a secondary analysis of de-identified data from a clinical trial including 9 sites across the United States. Preoperative biometry was used to predict postoperative RA with the implanted toric IOL using legacy enVista and EVO online calculators. The RA prediction error was computed between back-calculated postoperative RA and predicted residual RA. Outcome measures included vector (centroid) and arithmetic mean RA prediction error.Results: Comparison of calculators was based on 109 eyes, 97 (89%) of which were implanted with a toric IOL with an effective astigmatism power of 1.4 D or less. Centroid of the RA prediction errors was 0.37 D @ 178 and 0.17 D @ 090 for the legacy and EVO calculators, respectively (p < 0.0001). The proportion of eyes with an absolute RA prediction error ≤ 0.5 was 47.3% and 49.1% (p = 0.78), while the proportion of eyes ≤ 1.0 D was 82.7% and 89.1% (p = 0.03). Differences in the proportions ≤ 0.5 D existed for WTR (p = 0.015) but not ATR (p = 0.75) eyes. The proportion in which orientation of the predicted RA (ATR, WTR, or oblique) matched the actual RA was 62% and 78% for legacy and EVO calculators, respectively (p = 0.0029).Conclusion: The EVO Toric Formula v2.0 out-performed the legacy calculator with regards to predictions in eyes with low astigmatism.Keywords: cataract, toric, intraocular lens power, astigmatism, calculators, EVO
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1177-5483
Relation: https://www.dovepress.com/predictability-of-residual-postoperative-astigmatism-after-implantatio-peer-reviewed-article-OPTH; https://doaj.org/toc/1177-5483
URL الوصول: https://doaj.org/article/eef10c681afd4015991ddcd43a4c0ff7
رقم الأكسشن: edsdoj.f10c681afd4015991ddcd43a4c0ff7
قاعدة البيانات: Directory of Open Access Journals