دورية أكاديمية

Comparison of the Sensitivity and Specificity of Tzanck Smear and Immunofluorescence Assay for the Diagnosis of Cutaneous Herpes Simplex Virus and Varicella Zoster Virus Infections in a Real-life Clinical Setting

التفاصيل البيبلوغرافية
العنوان: Comparison of the Sensitivity and Specificity of Tzanck Smear and Immunofluorescence Assay for the Diagnosis of Cutaneous Herpes Simplex Virus and Varicella Zoster Virus Infections in a Real-life Clinical Setting
المؤلفون: Chayada Chaiyabutr, Nuttagarn Jantanapornchai, Chalermkwan Apinuntham, Charussri Leeyaphan, Sukhum Jiamton
المصدر: Siriraj Medical Journal, Vol 73, Iss 5 (2021)
بيانات النشر: Faculty of Medicine Siriraj Hospital, 2021.
سنة النشر: 2021
المجموعة: LCC:Medicine
مصطلحات موضوعية: Herpes simplex virus, varicella zoster virus, Tzanck smear, immunofluorescence, Medicine
الوصف: Objective: This research aim to compare (1) the sensitivities and specificities of Tzanck smears and indirect immunofluorescence assays (IFA) for cutaneous HSV and VZV infections in real-life settings; and (2) the detection rates of the tests for various patient types and lesion morphologies. Materials and Methods: This retrospective study reviewed 440 and 172 samples from patients with clinically suspicious cutaneous HSV and VZV infections, respectively. All patients underwent a Tzanck smear and IFA. The gold standard for the study was agreement of pre- and post-diagnostic coding (determined by a dermatologist) for cutaneous HSV and VZV infections. Results: For HSV infections, the respective sensitivity and specificity of Tzanck smears were 32.8% and 96.6%, whereas those for IFA were 60.7% and 100%. As to VZV infections, the sensitivity and specificity of Tzanck smears were 54.3% and 97.8%, respectively, while the corresponding IFA values were 71.7% and 100%. According to disease characteristics and lesion morphologies, the detection ability of cutaneous HSV by IFA was substantially higher than Tzanck smear especially in immunosuppressed condition. Tzanck smears and IFA demonstrated no statistical difference for early-onset ( 3 days) VZV infections. Conclusion: Tzanck smears and IFA had higher sensitivities for detecting VZV than HSV infections. IFA testing in suspected cutaneous HSV patients with immunosuppressed conditions should be recommended. Despite the overall sensitivity and specificity of IFA being greater than those for Tzanck smears especially in HSV infections, the latter test is a comparable option for early-onset VZV infections.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2228-8082
Relation: https://he02.tci-thaijo.org/index.php/sirirajmedj/article/view/245953; https://doaj.org/toc/2228-8082
DOI: 10.33192/Smj.2021.40
URL الوصول: https://doaj.org/article/f1a7f1f32d964138a21c7ecd3164f125
رقم الأكسشن: edsdoj.f1a7f1f32d964138a21c7ecd3164f125
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22288082
DOI:10.33192/Smj.2021.40