دورية أكاديمية

Utilizing Low-cost Vacuum-assisted Closure as Adjuvant Therapy in Soft Tissue Reconstruction for a Mangled Upper Extremity

التفاصيل البيبلوغرافية
العنوان: Utilizing Low-cost Vacuum-assisted Closure as Adjuvant Therapy in Soft Tissue Reconstruction for a Mangled Upper Extremity
المؤلفون: Meirizal Meirizal, MD, Rahadyan Magetsari, PhD, Sumadi Lukman Anwar, PhD, Mohammad Rizal Chaidir, PhD, Hilmi Muhammad, MD, Anak Agung Ngurah Nata Baskara, MD, Muhammad Fadhil Wasi Pradipta, MD, A Faiz Huwaidi, MD
المصدر: Plastic and Reconstructive Surgery, Global Open, Vol 12, Iss 5, p e5826 (2024)
بيانات النشر: Wolters Kluwer, 2024.
سنة النشر: 2024
المجموعة: LCC:Surgery
مصطلحات موضوعية: Surgery, RD1-811
الوصف: Summary:. Soft tissue reconstruction using flaps in managing mangled injuries is occasionally insufficient due to large defects and low flap viability. Conversely, delaying the closure of the defect can elevate the risk of infection. Adjuvant therapy becomes essential in the management of mangled injuries. We aim to present the use of low-cost vacuum-assisted closure (VAC) as an adjuvant therapy for mangled injuries. We reported the case of a 20-year-old man who sustained a mangled injury to his left forearm in a traffic accident 4 hours before admission. The mangled extremity severity score was 9; however, the patient declined amputation. Although the initial reconstruction was done, the flap could only cover vital structures. VAC was utilized to address the uncovered portion of the defect, to promote optimal granulation and prevent infection. The reconstruction proceeded with a skin graft and wrist arthrodesis. At 1-year follow-up, viable tissue was obtained but contracture occurred at the metacarpophalangeal and proximal interphalangeal joints. We intend to perform functional reconstruction at a later stage. Although the benefits of VAC in wound management are well established, reports regarding its advantages in mangled injury management remain relatively scarce. The high cost of VAC is a limiting factor, particularly in developing countries. This prompts the need for an affordable VAC innovation with comparable efficiency to the commercial model. Reverse Aqua Pump VAC, our innovative low-cost VAC, shows satisfactory outcomes in managing patients with mangled injuries with mangled extremity severity score indicating amputation.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2169-7574
00000000
Relation: http://journals.lww.com/prsgo/fulltext/10.1097/GOX.0000000000005826; https://doaj.org/toc/2169-7574
DOI: 10.1097/GOX.0000000000005826
URL الوصول: https://doaj.org/article/f458c9d720604533bdc67aa0d8b8316f
رقم الأكسشن: edsdoj.f458c9d720604533bdc67aa0d8b8316f
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21697574
00000000
DOI:10.1097/GOX.0000000000005826