دورية أكاديمية

Measurement properties of smartphone applications for the measurement of neck range of motion: a systematic review and meta analyses

التفاصيل البيبلوغرافية
العنوان: Measurement properties of smartphone applications for the measurement of neck range of motion: a systematic review and meta analyses
المؤلفون: E. Elgueta-Cancino, K. Rice, D. Abichandani, D. Falla
المصدر: BMC Musculoskeletal Disorders, Vol 23, Iss 1, Pp 1-17 (2022)
بيانات النشر: BMC, 2022.
سنة النشر: 2022
المجموعة: LCC:Diseases of the musculoskeletal system
مصطلحات موضوعية: Cervical spine, Range of motion, Movement, Neck pain, Reliability, Validity, Diseases of the musculoskeletal system, RC925-935
الوصف: Abstract Background Smartphone applications offer an accessible and practical option to measure neck range of motion (ROM) and are becoming more commonly used in clinical practice. We assessed the validity, reliability, and responsiveness of smartphone applications (apps) to measure neck ROM in people with and without neck pain. Methods A comprehensive electronic search strategy of the main electronic databases was conducted from inception until June 2021. The identified studies investigated apps which measured neck ROM, and evaluated their validity, reliability, or responsiveness, in adult participants with neck pain or asymptomatic individuals. Two independent reviewers determined eligibility and risk of bias following COSMIN guidelines. The quality of evidence was assessed according to the GRADE approach. Results Eleven studies, with a total of 376 participants were included. Three types of apps were identified: clinometer apps, compass apps, and other apps of ‘adequate’ to ‘doubtful’ risk of bias. A meta-analysis revealed ‘good’ to ‘excellent’ intra-rater and inter-rater reliability across the three types of apps. The overall validity was rated from ‘moderate’ to ‘very high’ across all apps. The level of evidence was rated as ‘low’ to ‘very low’. Conclusion Smartphone applications showed sufficient intra-rater reliability, inter-rater reliability, and validity to measure neck ROM in people with and without neck pain. However, the quality of evidence and the confidence in the findings are low. High-quality research with large sample sizes is needed to further provide evidence to support the measurement properties of smartphone applications for the assessment of neck ROM. Study registration Following indications of Prisma-P guidelines, this protocol was registered in PROSPERO on 1/05/2021 with the number CRD42021239501.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-2474
Relation: https://doaj.org/toc/1471-2474
DOI: 10.1186/s12891-022-05066-6
URL الوصول: https://doaj.org/article/f70dd59882364e19b24ca8a22154f77a
رقم الأكسشن: edsdoj.f70dd59882364e19b24ca8a22154f77a
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14712474
DOI:10.1186/s12891-022-05066-6