دورية أكاديمية

Sling for the sling: a new technique for long-term correction of severe congenital ptosis

التفاصيل البيبلوغرافية
العنوان: Sling for the sling: a new technique for long-term correction of severe congenital ptosis
المؤلفون: Ahmed N. Kotb, Noha M. Soliman, Ahmer Raza, Noran A. Nour, Hala K. Mattout
المصدر: BMC Ophthalmology, Vol 24, Iss 1, Pp 1-7 (2024)
بيانات النشر: BMC, 2024.
سنة النشر: 2024
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: Congenital ptosis, Silicon rods ptosis sling, Ethibond sutures, Sling for sling, Ophthalmology, RE1-994
الوصف: Abstract Introduction Severe congenital ptosis poses a complex challenge for oculoplastic surgeons, requiring meticulous surgical intervention to restore eyelid function and improve aesthetic outcomes mainly by using frontalis sling approach. A crucial issue in frontalis sling surgeries is the sustainability of effect. Purpose This retrospective study reports the outcomes of two surgical techniques for treating severe congenital ptosis in the paediatric age group: Silicon rods ptosis sling and a novel technique involving the use of Silicon rods with green braided polyester (Ethibond) sutures to secure the rods in place “sling for the sling”. Methods The medical records of children who underwent frontalis suspension were reviewed in a retrospective fashion. We identified two groups; the first group (20 patients: 35 eyelids) had the traditional frontalis suspension surgery using silicone suspension set, the second group (14 patients: 25 eyelids) was operated using the new “sling for sling” technique. We used the postoperative marginal reflex distance-1 (MRD-1) as the primary outcome measure while the frequency of both wound related complications and recurrence were considered as secondary outcome measures. Post operative data were collected and compared after 1 month, 6 months, 12 months, and 18 months. Results Preliminary results indicate promising outcomes for both techniques, with significant improvement in eyelid elevation observed in both groups. However, the novel technique using Silicon rods with Ethibond sutures demonstrated enhanced sustainability, leading to a more durable outcome with significantly less recurrence. Conclusion This study highlights the potential benefits of the novel technique in treating severe congenital ptosis and introduces an innovative approach to Silicone rods fixation to achieve a long-term corrective effect.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 1471-2415
Relation: https://doaj.org/toc/1471-2415
DOI: 10.1186/s12886-024-03371-3
URL الوصول: https://doaj.org/article/fa8b8634d5f74acaa955599f0bc494ee
رقم الأكسشن: edsdoj.fa8b8634d5f74acaa955599f0bc494ee
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:14712415
DOI:10.1186/s12886-024-03371-3