دورية أكاديمية

An experimental study to determine the effectiveness of blunt pressure technique on pain response among patients receiving intramuscular injection

التفاصيل البيبلوغرافية
العنوان: An experimental study to determine the effectiveness of blunt pressure technique on pain response among patients receiving intramuscular injection
المؤلفون: Dinesh Kumar Suganandam, Jasmin Ruby Anand, Amala Rajan, Georgene Singh, Bijesh Kumar Yadav
المصدر: Indian Journal of Pain, Vol 34, Iss 1, Pp 34-38 (2020)
بيانات النشر: Wolters Kluwer Medknow Publications, 2020.
سنة النشر: 2020
المجموعة: LCC:Neurology. Diseases of the nervous system
مصطلحات موضوعية: blunt pressure, intramuscular injection, pain, procedural pain, Neurology. Diseases of the nervous system, RC346-429
الوصف: Context: Pain is a universal phenomenon. It is considered to be the “fifth vital sign.” Pain originating from intramuscular (IM) injection should not be underestimated, because a painful injection might incite severe fear of injection, which may delay the patient seeking medical help. Aims: This study was intended to determine the effectiveness of blunt pressure technique on pain response among subjects receiving IM injection. Settings and Design: Using Quantitative approach, randomized controlled trial with posttest only design was undertaken for 6 a period of 6 weeks in a tertiary care centre. Materials and Methods: Patients receiving IM injection in the injection room were selected using consecutive sampling technique. The individuals were randomly allocated to control and experimental arm using computer generated random number table in the sealed envelope. Patients with infectious skin diseases, bleeding disorder, trauma and injury, cognitive impairment were excluded from the study. Control arm received injection using standard technique and experimental arm received injection using blunt pressure technique with the operation protocol. Numerical pain rating scale was used to collect the data. Statistical Analysis Used: Descriptive statistics was used to describe the data. Mann–Whitney U-test and Kruskal–Wallis test were used to infer the data. Results: The mean pain response in the standard technique was 3.15 ± 1.44 and in the blunt pressure technique was 1.01 ± 0.98. The difference in pain response was found to be statistically significant (P < 0.001). Conclusions: Blunt pressure technique is found to be effective in reducing the pain response. Nurses can embrace this innovative technique with scientific base to alleviate the procedural pain.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 0970-5333
Relation: http://www.indianjpain.org/article.asp?issn=0970-5333;year=2020;volume=34;issue=1;spage=34;epage=38;aulast=Suganandam; https://doaj.org/toc/0970-5333
DOI: 10.4103/ijpn.ijpn_51_19
URL الوصول: https://doaj.org/article/fb1e8cebc6fd4c929467d02805cf0744
رقم الأكسشن: edsdoj.fb1e8cebc6fd4c929467d02805cf0744
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:09705333
DOI:10.4103/ijpn.ijpn_51_19