دورية أكاديمية

Evaluation of early results of quick-chop phacoemulsification in the patients with high myopic cataract

التفاصيل البيبلوغرافية
العنوان: Evaluation of early results of quick-chop phacoemulsification in the patients with high myopic cataract
المؤلفون: Ali Akal, Tugba Goncu, Sevin Soker Cakmak, Isa Yuvaci, Mustafa Atas, Süleyman Demircan, Omer Faruk Yilmaz
المصدر: International Journal of Ophthalmology, Vol 7, Iss 5, Pp 828-831 (2014)
بيانات النشر: Press of International Journal of Ophthalmology (IJO PRESS), 2014.
سنة النشر: 2014
المجموعة: LCC:Ophthalmology
مصطلحات موضوعية: high myopia, cataract, quick-chop phacoemulsification, intraocular lens, Ophthalmology, RE1-994
الوصف: AIM:To assess the early surgical outcomes ofquick-chop phacoemulsification technique in patients with high myopia.METHODS: The data of patients with high myopia who underwent quick-chop phacoemulsification were reviewed retrospectively. There were 42 eyes of 31 patients. The axial length was more than 26 mm in all eyes. All eyes underwent quick-chop phacoemulsification surgery with the placement of an intraocular lens (IOL) in the capsular bag. Postoperative visits were performed at 1, 3d; 2wk, 1mo. Early postoperative best corrected visual acuity (BCVA), preoperative and postoperative corneal endothelial cell density (ECD), central corneal thickness (CCT) and postoperative complications were assessed. Paired sample t-test or Wilcoxon tests were used to compare data between preoperative and postoperative data.RESULTS:There was no statistically significant difference between preoperative and postoperative ECD and CCT. Retinal detachment was developed in one eye at postoperative first day. There was an iris prolapsus from side port insicion.CONCLUSION: Quick-chop phacoemulsification technique is a safe surgical technique. However we can encounter some complications in high myopic eyes due to histopathological differences. Both side port and clear corneal tunnel insicion size is crucial for preventing postoperative complications. If any persistent leakage is noticed, suture should be placed.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2222-3959
2227-4898
Relation: http://www.ijo.cn/en_publish/2014/5/20140516.pdf; https://doaj.org/toc/2222-3959; https://doaj.org/toc/2227-4898
DOI: 10.3980/j.issn.2222-3959.2014.05.16
URL الوصول: https://doaj.org/article/fc0c34f462f4425fb5c6cb203464000e
رقم الأكسشن: edsdoj.fc0c34f462f4425fb5c6cb203464000e
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:22223959
22274898
DOI:10.3980/j.issn.2222-3959.2014.05.16