دورية أكاديمية

An Integrated Transformer Design With a Center-Core Air-Gap for DAB Converters

التفاصيل البيبلوغرافية
العنوان: An Integrated Transformer Design With a Center-Core Air-Gap for DAB Converters
المؤلفون: Eun S. Lee, Jin H. Park, Myung Y. Kim, Seung H. Han
المصدر: IEEE Access, Vol 9, Pp 121263-121278 (2021)
بيانات النشر: IEEE, 2021.
سنة النشر: 2021
المجموعة: LCC:Electrical engineering. Electronics. Nuclear engineering
مصطلحات موضوعية: Transformer design, integrated transformer, transformer leakage, leakage inductance, dual-active-bridge (DAB) converter, DC/DC converter, Electrical engineering. Electronics. Nuclear engineering, TK1-9971
الوصف: In this paper, an integrated transformer design methodology for dual-active-bridge (DAB) converters, which basically utilize leakage inductance so as to substitute a cumbersome inductor in the conventional DAB converters, is newly proposed. The proposed integrated transformer with integrated leakage inductance inherently includes leakage inductance and magnetizing inductance, whose values can be appropriately selected by modulating the number of turns and the center-core air-gap. Based on the theoretical analysis of the DAB converters, the major parameters, i.e., primary and secondary current levels and its phase difference, can be derived, and these values are utilized for magnetic analysis of the proposed integrated transformer. Considering core loss and copper loss of the proposed integrated transformer in the DAB converters, optimal values of the center-core air-gap $l_{g}$ and the optimal number of turns $N_{\mathrm {1,}op} ~\&~ N_{\mathrm {2,}op}$ can be determined so that high power efficiency is achieved at a normal operating point of the DAB converters. The 20W prototypes of the DAB converter with EER2834 and EER3019 of the ferrite cores were fabricated and verified by simulation and experiment. The design results showed that the optimal number of turns at $l_{g} =2.0$ mm are found to be 11 and 10, for the EER2834 and EER3019, respectively. Compared to 94.5% and 96.3% of AC efficiencies for the conventional transformer and inductor set, the proposed integrated transformer achieved 95.8% and 96.9% of AC efficiencies at maximum power transfer point of $\theta _{p} = \pi $ /2 for EER2834 and EER3019, respectively.
نوع الوثيقة: article
وصف الملف: electronic resource
اللغة: English
تدمد: 2169-3536
Relation: https://ieeexplore.ieee.org/document/9525074/; https://doaj.org/toc/2169-3536
DOI: 10.1109/ACCESS.2021.3108837
URL الوصول: https://doaj.org/article/acff49104b884339928510c4855a6a3e
رقم الأكسشن: edsdoj.ff49104b884339928510c4855a6a3e
قاعدة البيانات: Directory of Open Access Journals
الوصف
تدمد:21693536
DOI:10.1109/ACCESS.2021.3108837