مورد إلكتروني
Ocjena točnosti mjerenja okomitih dimenzija na ortopantomogramima
العنوان: | Ocjena točnosti mjerenja okomitih dimenzija na ortopantomogramima |
---|---|
عناروين إضافية: | Assessment of the Precision of Vertical Measurements of Orthopantomographic Radiographs |
المصدر: | Acta stomatologica Croatica : International journal of oral sciences and dental medicine; ISSN 0001-7019 (Print); ISSN 1846-0410 (Online); Volume 32; Issue 2 |
بيانات النشر: | School of Dental Medicine, University of Zagreb, Croatian Dental Society - Croatian Medical Association 1998 |
تفاصيل مُضافة: | Asja Čelebić Amir Ćatić Malita Valentić- Peruzović Adnan Ćatović Ivan Vinter Ivana Muretić |
نوع الوثيقة: | Electronic Resource |
مستخلص: | Svrha istraživanja bila je ocijeniti točnost prikaza okomitih dimenzija na ortopantomogramima. Različite okomite udaljenosti označene su na 25 mandibula s pomoću metalnih markera veličine 1 mm2. Označene udaljenosti izmjerene su pomičnom kliznom mjerkom (TMA-MEBA), a zatim su napravljeni ortopantomogrami tih mandibula. Iste udaljenosti izmjerene su i na panoramskim snimkama. Dobiveni rezultati analizirani su statistički. Čimbenik povećanja izračunan na osnovi dobivenih rezultata uglavnom je manji od deklariranog (l,22x), iako razlika nije statistički znatna za većinu mjerenih varijabla. Nasuprot stajalištima u literaturi, naši rezultati pokazuju da je moguće precizno mjeriti okomite udaljenosti na ortopantomogramima čak i u anteriornoj regiji mandibula, pod uvjetom da se mandibule ispravno pozicioniraju i da su obuhvaćene fokalnim kanalom radiološkog aparata. The objective of this study was to evaluate the precision of the vertical dimensional measurements on orthopantomographic images, and therefore to evaluate their dimensional reliability. Different distances denoted by metal markers were measured on 25 dry mandibles. The same measurements were repeated on panoramic radiographs o f those mandibles and the results were statistically analysed. The calculated magnification factors for the vertical measurements were, in general, smaller than the manufacturer of the X-ray device declares, although the difference was not statistically significant for the most variables. Opposite to some opinions, our results reveal that the vertical measurements on orthopantomograms are precise enough even in the anterior region of the mandible, if the mandibles are adequately positioned and encompassed in the focal through of the machine. |
مصطلحات الفهرس: | ortopantomografija; indeks povećanja, orthopantomographic radiography; vertical distances, text, info:eu-repo/semantics/article, info:eu-repo/semantics/publishedVersion |
URL: | |
الإتاحة: | Open access content. Open access content info:eu-repo/semantics/openAccess Copyright: Author’s. Published by: University of Zagreb School of Dental Medicine; Croatian Dental Society, Croatian Medical Association. All articles are freely available under the terms of the Creative Commons Attribution-NonCommercial-NoDerivates 4.0 International Licence. This license allows others to download works and share them with others as long as they credit you, but they can’t change them in any way or use them commercially. https://creativecommons.org/licenses/by-nc-nd/4.0/legalcode Annual subscription fee for printed journal Abroad: 50€ for Europe and 60€ outside Europe to be paid to account No. IBAN: HR7423600001101235285, SWIFT: ZABA HR2X Zagrebacka banka marked “For ASCRO”. |
ملاحظة: | application/pdf English Croatian |
أرقام أخرى: | HRCAK oai:hrcak.srce.hr:97867 840811353 |
المصدر المساهم: | HRCAK PORTAL ZNANSTVENIH CASOPISA REPUB From OAIster®, provided by the OCLC Cooperative. |
رقم الأكسشن: | edsoai.ocn840811353 |
قاعدة البيانات: | OAIster |
الوصف غير متاح. |