مورد إلكتروني
Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals
العنوان: | Active concentric ring electrode for non-invasive detection of intestinal myoelectric signals |
---|---|
بيانات النشر: | Elsevier Hispana 2011-05 |
تفاصيل مُضافة: | Universitat Politècnica de València. Departamento de Ingeniería Electrónica - Departament d'Enginyeria Electrònica Universitat Politècnica de València. Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano - Institut Interuniversitari d'Investigació en Bioenginyeria i Tecnologia Orientada a l'Ésser Humà Ministerio de Educación y Ciencia Prats Boluda, Gema Garcia Casado, Francisco Javier Martínez De Juan, José Luís Ye Lin, Yiyao |
نوع الوثيقة: | Electronic Resource |
مستخلص: | [EN] Although the surface electroenterogram (EEnG) is a weak signal contaminated by strong physiological interference, such as ECG and respiration, abdominal surface recordings of the EEnG could provide a non-invasive method of studying intestinal activity. The goal of this work was to develop a modular, active, low-cost and easy-to-use sensor to obtain a direct estimation of the Laplacian of the EEnG on the abdominal surface in order to enhance the quality of bipolar surface monitoring of intestinal activity. The sensor is made up of a set of 3 concentric dry Ag/AgCl ring electrodes and a battery-powered signal-conditioning circuit. Each section is etched on a different printed circuit board (PCB) and the sections are joined to each other by surface mount technology connectors. This means the sensing electrodes can be treated independently for purposes of maintenance and replacement and the signal conditioning circuit can be re-used. A total of ten recording sessions were carried out on humans. The results show that the surface recordings of the EEnG obtained by the active sensor present significantly less ECG and respiration interference than those obtained by bipolar recordings. In addition, bioelectrical sources whose frequency fitted with the slow wave component of the EEnG (SW) were identified by parametric spectral analysis in the surface signals picked up by the active sensors. © 2010 IPEM. |
مصطلحات الفهرس: | Active sensor, Concentric electrode, Electroenterogram, Laplacian, Non-invasive, Small intestine, Surface recording, Laplacians, Electrocardiography, Electrochromic devices, Electrodes, Laplace transforms, Physiology, Sensors, Spectrum analysis, Surface mount technology, Printed circuit boards, Article, Bioenergy, Biosensor, Biotechnology, Breathing, Electric current, Electrode, Electroenterography, Functional assessment, Intestine function, Intestine muscle, Muscle action potential, Non invasive procedure, Priority journal, Spectroscopy, Abdomen, Electromyography, Humans, Intestines, Male, Signal Processing, Computer-Assisted, TECNOLOGIA ELECTRONICA, info:eu-repo/semantics/article |
URL: | |
الإتاحة: | Open access content. Open access content http://rightsstatements.org/vocab/InC/1.0 info:eu-repo/semantics/closedAccess |
ملاحظة: | TEXT English |
أرقام أخرى: | UPV oai:riunet.upv.es:10251/62720 urn:issn:1350-4533 info:doi:10.1016/j.medengphy.2010.11.009 21163682 https://riunet.upv.es/bitstream/10251/62720/4/Prats;Garcia;Martínez - Active concentric ring electrode for non-invasive detection of intestinal....pdf.jpg 1006857166 |
المصدر المساهم: | UNIVERSITAT POLITECNICA DE VALENCIA From OAIster®, provided by the OCLC Cooperative. |
رقم الأكسشن: | edsoai.on1006857166 |
قاعدة البيانات: | OAIster |
الوصف غير متاح. |