مورد إلكتروني

Utvärdering av koldioxidmätaren Vaisala GMP343 samt sambandet mellan grundvattennivå och koldioxidavgång från torvjordar

التفاصيل البيبلوغرافية
العنوان: Utvärdering av koldioxidmätaren Vaisala GMP343 samt sambandet mellan grundvattennivå och koldioxidavgång från torvjordar
عناروين إضافية: Evaluation of the Vaisala GMP343 carbon dioxide meter and the relationship between groundwater level and carbon dioxide emissions from peat soils
بيانات النشر: SLU/Dept. of Soil and Environment 2010
تفاصيل مُضافة: Öhrlund, Isak
نوع الوثيقة: Electronic Resource
مستخلص: The research group Soil and Water Management at the department of Soil and Environment at the Swedish University of Agricultural Sciences in Uppsala are studying greenhouse gas emissions from cultivated peat soils. To measure carbon dioxide emissions from peat soils in the field the research group are now using two portable carbon dioxide meters (Vaisala GMP343). For practical reasons, they plan to acquire a new type of automated field meter. The aim of this study is to evaluate the present meters to see how environmental conditions and instrument settings affect the results, which is meant to facilitate the introduction of the new field meter when the meters needs to be compared. As a part of the study the relationship between groundwater level and carbon dioxide emissions from peat soils will be investigated. The evaluation of the two carbon dioxide meters was made by connecting them to one single airtight system, with the aim of creating identical measurement environments. Various factors such as warm-up time and flow rate was tested to see how they affect the results, and to see if there are any disparities between the meters. The relationship between groundwater level and carbon dioxide emission was investigated by adjusting the groundwater level in three different peat soil profiles from Örke in Sweden (60 ° N, 17 ° E) in a temperature regulated laboratory. The carbon dioxide emissions from the profiles were measured using a Vaisala GMP343 carbon dioxide meter at groundwater levels 0, -5, -20, -30 and -40 cm. The results from the evaluation of the carbon dioxide emission meters show that there are some differences between the meters that needs to be taken into account when measurements are made. The most important discovery is that the two meters registers different carbon dioxide concentrations, and that the difference between them is not constant at different concentrations. The observed difference can introduce systematic errors when both meters are used in
مصطلحات الفهرس: Vaisala GMP343, växthusgasavgång, grundvattennivå, torvjord, koldioxid, CO2, M2
URL: https://stud.epsilon.slu.se/1588/
الإتاحة: Open access content. Open access content
ملاحظة: Swedish
English
أرقام أخرى: SESVR oai:stud.epsilon.slu.se:1588
1121562250
المصدر المساهم: SVERIGES LANTBRUKSUNIVERSITET, SLU
From OAIster®, provided by the OCLC Cooperative.
رقم الأكسشن: edsoai.on1121562250