مورد إلكتروني

Framtidens slamhantering vid Roslagsvatten : Behandling av kommunalt orötat slam med HTC-teknik (OxyPower HTC™) och rening av HTC-vatten med SBR och MBBR

التفاصيل البيبلوغرافية
العنوان: Framtidens slamhantering vid Roslagsvatten : Behandling av kommunalt orötat slam med HTC-teknik (OxyPower HTC™) och rening av HTC-vatten med SBR och MBBR
عناروين إضافية: Future sludge management at Roslagsvatten WWTP : Treatment of municipal undigested sludge with HTC-technology (OxyPower HTC™) and purification of HTC-water with SBR and MBBR
بيانات النشر: IVL Svenska Miljöinstitutet 2023
تفاصيل مُضافة: Baresel, Christian
Bornold, Niclas
Malovanyy, Andriy
Axegård, Peter
Lazic, Aleksandra
Yang, Jing-Jing
نوع الوثيقة: Electronic Resource
مستخلص: Hydrotermisk karbonisering (HTC) av avloppsslam har potential att bli en av teknikerna för framtidens slamhantering vid svenska kommunala avloppsreningsverk (ARV). HTC-tekniken bygger på en process där slammet eller andra substrat behandlas under högt tryck (>20 bar) och under hög temperatur (180-260 °C). HTC-processen genererar hydrokol som kan avvattnas mekaniskt till höga torrhalter (>60 % TS). Några förväntade fördelar med HTC-tekniken är en mer hållbar återföring av närsalter via det producerade hydrokolet, samt andra positiva effekter som t.ex. mindre växthusgasutsläpp och närsaltläckage till miljön. Samtidigt finns vissa utmaningar, som t.ex. hantering av processvatten, som behöver hanteras och oklarheter kring det hydrokolets egenskaper som behöver utredas. För att besvara dessa frågeställningar och samla in praktiska erfarenheter från HTC som slamhanteringsalternativ har pilotförsök med både HTC-behandling och våtoxidation av HTC-vatten genomförts. Orötat slam behandlades för att produce¬ra hydrokol och det producerade HTC-vattnet undersöktes vid pilotanläggning Hammarby Sjöstadsverk i bänk- och pilotskaletester för biologisk rening i sido- eller huvudström. Med avsikt att studera potential för jordförbättring och näringsegenskaper för hydrokol och slam från Roslagsvattens avloppsreningsverk i Margretelund karakteriserades och testades i odlingsförsök med jord och torv. Även bildningen av koldioxid i jord utvärderades. I dessa studier jämfördes resultaten även med hydrokol från fyra andra substrat (rötrest från matrester, stallgöd¬sel, bioslam från rening av processvatten från massa/pappersbruk samt rötat blandslam från ARV). Projektet har visat att C-Greens OxyPower HTC™ är ett tekniskt möjligt alternativ för att behandla Margretelunds orötade avloppsslam. Olika tester har illustrerat att tekniken kan minska slamvolymen genom en ökning av TS till ca 65 % inte bara för reningsverkets slam utan även för ett antal andra undersökta organiska substrat
Hydrothermal carbonization (HTC) of municipal sewage sludge has the potential to become one of the techniques for future sludge management at Swedish municipal wastewater treatment plants (WWTPs). Some expected benefits of the HTC technology are a more sustainable sludge management and return of nutrients via the produced hydrochar, as well as other positive effects such as less greenhouse gas emissions and nutrient leakage into the environment. At the same time, certain challenges such as the handling of process water and uncertainties about the properties of the produced hydrochar need to be investigated. In order to answer these questions and gather practical experience for HTC as a sludge management alternative, pilot trials with C-Green's OxyPower HTC™ have been carried out at Roslagsvattens WWTP in Margretelund, Åkersberga, Sweden. Undigested sludge was treated to produce hydrochar and the produced HTC water was used at KTH/IVL's pilot plant Hammarby Sjöstadsverk in various side- or mainstream bench- and pilot-scale tests for biological treatment.Hydrochar and sludge from Roslagsvattens WWTP in Margretelund were characterized and tested in growth trials with soil and peat. The formation of carbon dioxide in soil was also evaluated. In these studies, the results were also compared with hydrochar from four other substrates (digested food waste, stable manure, biosludge from treatment of process water from a pulp/paper mill and digested mixed sludge from municipal WWTPs).The project has shown that C-Green's OxyPower HTC™ is a possible technical alternative for treating Margretelund’s undigested sewage sludge. Various tests have illustrated that the technol¬ogy can reduce the sludge volume through an increase in TS to about 65 %, not only for sewage sludge but also for several other investigated substrates. Although the HTC pilot plant could not be run continuously as a full-scale plant, still a process stability could be demonstrated. Even though the process is b
مصطلحات الفهرس: HTC, sludge handling, hydrochar, sewage treatment plant, sludge spreading, Revaq, slamhantering, hydrokol, avloppsreningsverk, slamspridning, Water Treatment, Vattenbehandling, Report, info:eu-repo/semantics/report, text
URL: http://urn.kb.se/resolve?urn=urn:nbn:se:ivl:diva-4153
B-rapport ; B2460
الإتاحة: Open access content. Open access content
info:eu-repo/semantics/openAccess
ملاحظة: application/pdf
Swedish
أرقام أخرى: UPE oai:DiVA.org:ivl-4153
urn:isbn:978-91-7883-471-6
1372210719
المصدر المساهم: UPPSALA UNIV LIBR
From OAIster®, provided by the OCLC Cooperative.
رقم الأكسشن: edsoai.on1372210719
قاعدة البيانات: OAIster