دورية أكاديمية

Low-Frequency Pitch Perception in Cochlear Implant Recipients with Normal Hearing in the Contralateral Ear

التفاصيل البيبلوغرافية
العنوان: Low-Frequency Pitch Perception in Cochlear Implant Recipients with Normal Hearing in the Contralateral Ear
اللغة: English
المؤلفون: Dillon, Margaret T., Buss, Emily, Rooth, Meredith A., King, English R., Pillsbury, Harold C., Brown, Kevin D.
المصدر: Journal of Speech, Language, and Hearing Research. Aug 2019 62(8):2860-2871.
الإتاحة: American Speech-Language-Hearing Association. 2200 Research Blvd #250, Rockville, MD 20850. Tel: 301-296-5700; Fax: 301-296-8580; e-mail: slhr@asha.org; Web site: http://jslhr.pubs.asha.org
Peer Reviewed: Y
Page Count: 12
تاريخ النشر: 2019
نوع الوثيقة: Journal Articles
Reports - Research
Descriptors: Assistive Technology, Auditory Perception, Adults, Hearing Impairments, Accuracy, Longitudinal Studies, Acoustics, Cues, Cognitive Processes
DOI: 10.1044/2019_JSLHR-H-18-0409
تدمد: 1092-4388
مستخلص: Purpose: Three experiments were carried out to evaluate the low-frequency pitch perception of adults with unilateral hearing loss who received a cochlear implant (CI). Method: Participants were recruited from a cohort of CI users with unilateral hearing loss and normal hearing in the contralateral ear. First, low-frequency pitch perception was assessed for the 5 most apical electrodes at 1, 3, 6, and 12 months after CI activation using an adaptive pitch-matching task. Participants listened with a coding strategy that presents low-frequency temporal fine structure (TFS) and compared the pitch to that of an acoustic target presented to the normal hearing ear. Next, participants listened with an envelope-only, continuous interleaved sampling strategy. Pitch perception was compared between coding strategies to assess the influence of TFS cues on lowfrequency pitch perception. Finally, participants completed a vocal pitch-matching task to corroborate the results obtained with the adaptive pitch-matching task. Results: Pitch matches roughly corresponded to electrode center frequencies (CFs) in the CI map. Adaptive pitch matches exceeded the CF for the most apical electrode, an effect that was larger for continuous interleaved sampling than TFS. Vocal pitch matches were variable but correlated with the CF of the 3 most apical electrodes. There was no evidence that pitch matches changed between the 1- and 12-month intervals. Conclusions: Relatively accurate and asymptotic pitch perception was observed at the 1-month interval, indicating either very rapid acclimatization or the provision of familiar place and rate cues. Early availability of appropriate pitch cues could have played a role in the early improvements in localization and masked speech recognition previously observed in this cohort.
Abstractor: As Provided
Entry Date: 2019
رقم الأكسشن: EJ1225222
قاعدة البيانات: ERIC
الوصف
تدمد:1092-4388
DOI:10.1044/2019_JSLHR-H-18-0409